Product Details:
Air Compressor Model | CF series |
Material | Mild Steel |
Compressor Type | Screw Compressor |
Operating Pressure | 20 Bar |
Volume Flow Rate | 72 To 2760 Nm3/h |
Connections | 3/8'' To 3'' |
Operating Temp. Range | 1,5 To 65 DegreeC |
Standard Colour | RAL 5012 |
Product Code: CF series
CF filters are designed for protection of the downstream compressed air system with pressure up to 20 bar against defects and other failures. They ensure high efficient removal of solid particles, water, oil aerosols, hydrocarbons, odour and vapours from compressed air systems. Required compressed air quality according to standard ISO 8571-1 can be achieved with 6 different grades of filter elements (B, P, R, M, S and A). Optional internal and external condensate drains should be used for efficient condensate draining from filter housing.
Product Details:
Filter Type | AF HT series |
Operating Pressure | 16 Bar |
Volume Flow Rate | 60 To 2760 Nm3/h |
Connections | 3/8'' To 3'' |
Operating Temp. Range | 1,5 To 120 DegreeC |
Standard Colour | RAL 5012 |
Product Code: AF HT series
AF HT filter housings are designed for very high efficient removal of solid particles, water and oil aerosols, from compressed air systems in high temperature applications. To meet the required compressed air quality, appropriate filter element (BHT, N25HT, N5HT, RHT, MHT, SHT) must be installed into filter housing.
Product Details:
Air Compressor Model | P-VAC series |
Material | Aluminium |
Operating Pressure | 20 To 2000 Bar(abs) |
Volume Flow Rate | 7,5 To 345 Nm3/h |
Connections | 3/8'' To 3'' |
Operating Temp. Range | 1,5 To 65 DegreeC |
Standard Colour | RAL 5012 |
P-VAC filters are designed for protection of vacuum pumps. These filters are optimized for high-efficient removal of solid particles and other contamination from the suction side of vacuum pumps preventing damage to the pump. Two filtration stages are available for P-VAC filters. Rough prefilter “VACP” removes bulk liquid and large solid particles, while high efficiency microfilter VACM removes very fine impurities which may damage the pump.
Product Details:
Air Compressor Model | AAF series |
Applications | General Industrial Applications |
Operating Pressure | 16 Bar |
Volume Flow Rate | 10 To 780 Nm3/h |
Connections | 1/8'' To 1 1/2'' |
Operating Temp. Range | 1,5 To 65 DegreeC |
Standard Colour | RAL 5012, RAL 7040 |
AAF filters are designed for protection of the downstream compressed air system and equipment with lower air flows against defects and other failures. They ensure high efficient removal of solid particles, water, oil aerosols, hydrocarbons, odour and vapours from compressed air systems up to 16 bar. Required compressed air quality according to standard ISO 8571-1 can be achieved with 5 different grades of filter elements (P, R, M, S and A). Optional internal and external condensate drains should be used for efficient condensate draining from filter housing.
Product Details:
Air Compressor Model | BF series |
Operating Pressure | 16 Bar |
Volume Flow Rate | 1680 To 31400 Nm3/h |
Connections | DN80 To DN300 |
Operating Temp. Range | 1,5 To 65 DegreeC |
Standard Colour | RAL 5012 |
BF filters are designed for protection of the downstream compressed air system and equipment against defects and other failures. Due to their robust welded carbon steel construction, are used for installation in heavy industrial applications with high air flows.They ensure high efficient removal of solid particles, water, oil aerosols, hydrocarbons, odour and vapours from compressed air systems up to 16 bar. Required compressed air quality according to standard ISO 8571-1 can be achieved with 6 different grades of filter elements (B, P, R, M, S and A). Optional external condensate drains should be used for efficient condensate draining from filter housing. Fluid group 1 on request.
Product Details:
Air Compressor Model | AV series |
Material | Stainless Steel |
Compressor Type | Reciprocating Compressor, Centrifugal Compressor |
Volume Flow Rate | 9 To 310 Nm3/h |
Connections | DN32 To DN80 |
Operating Temp. Range | Up To 200 DegreeC |
AV stainless steel filter housings are designed to remove impurities from air which is being feed or exhausted from tank during changing of liquid level. To meet the required air quality appropriate filter element (typically AVF filtration grade) must be installed into filter housing. AV filter housing is also designed for sterilisation. Before use, if needed for the application, sterilize the filters.
Product Details:
Usage/Application | Compressed Air Systems |
Flow Rate | 110 To 1000 Nm3/h |
Operating Pressure | 4 to16 Bar |
Operating Temp. Range | 1,5 To 60 DegreeC |
Pressure Dew Points | -40 DegreeC (-25 DegreeC /-70 DegreeC) |
Standard Colour | RAL 5012 |
Average Compressed Air Consumption | 15-20% |
Product Code: B-DRY series
B-DRY adsorption dryers are designed for continuous separation of water vapour from the compressed air thus reducing the pressure dew point. B-DRY series dryer consists of two columns, filled with desiccant beds, controller with LCD display, valves, manometers, support construction and suitable filter housings with the required filter element. Adsorption takes place under pressure in the first column while the second column regenerates with a portion of already dried compressed air at ambient pressure. When the first column is saturated to a certain level column switch-over is carried out and the process of adsorption continues in the second column without any drop of pressure at the outlet of the dryer. Regeneration of saturated desiccant is possible because a small portion of already dry compressed air is decompressed and when expanded it becomes extremely dry.
Product Details:
Air Compressor Model | SPF series |
Material | Stainless Steel |
Operating Pressure | 16 (12) bar |
Volume Flow Rate | 75 To 3600 Nm3/h |
Connections | 1/4'' To 3'' |
Operating Temp. Range | Upto 150 DegreeC |
SPF stainless steel sterile filter housings are specially designed for applications in process industry, where the risk for corrosion of compressed air system components is very high.Required compressed air quality according to standard ISO 8571-1 can be achieved with appropriate filter element. SPF process filter housing can be used in variety of applications. For applications not listed please contact producer or your local distributor. For oil removal, coalescing filter element must be installed and flow direction inside-out must be provided. General arrangement is filter head on the bottom and filter bowl on the top. Fluid group 1 on request.
Product Details:
Air Compressor Model | WFIF series |
Material | Stainless Steel |
Operating Pressure | 16 (12,10) Bar |
Volume Flow Rate | 150 To 21120 Nm3/h |
Connections | DN15 To DN200 |
Operating Temp. Range | Upto 150 DegreeC |
WFIF welded stainless steel filter housings with flange connections are designed filtration of compressed air as well as many other gasses where the risk for corrosion is very high or where stainless steel housing is required. Required compressed air quality according to standard ISO 8571-1 can be achieved with 8 different grades of filter elements (PI, PIW, PN, PP, PR, PM, PS and PA). Fluid group 1 on request. Optional external condensate drains should be used for efficient condensate draining from filter housing.
Product Details:
Frequency | 56/60Hz |
Brand | Nitrogenium |
I Deal In | New Only |
Drying Capacity | 0-2200 Nm3/hr |
Dryer Technology | Dessicant |
Automation Grade | Automatic |
Voltage | 230V |
Maximum Pressure | 16 Bar |
Air Flow Rate | 110 Nm3/h |
Warranty | 12 months |
Product Details:
Usage/Application | Compressed Air Systems |
Automation Grade | Automatic |
Flow Rate | 6 To 6.500 Nm3/h |
Operating Pressure | 4 - 14 Bar |
Operating Temp. Range | 1,5 DegreeC To 55 DegreeC |
Pressure Dew Points | Down To -40 DegreeC |
Average Compressed Air Consumption | 4,6 % |
Product Code: COM-DRY series
COM-DRY series
COM-Dry dryers have been designed for continuous separation of water vapour from compressed air thus reducing dew point. Drying consist of two steps. Refrigerant dryer first eliminates large majority of water and reduces dew point down to PDP +3°C. Further reduction of dew point is carried out by adsorption dryer. Operation of dryer is more simple compared to conventional heat regenerated adsorption dryer while average compressed air losses present only up to 4,6 %.
Product Details:
Usage/Application | Compressed Air Systems |
Automation Grade | Automatic |
Dryer Technology | Dessicant |
Minimum Output Dew Point | -40 C |
Flow Rate | 390 To 20200 Nm3/h |
Operating Pressure | 4 To 11 Bar |
Operating Temp. Range | 1,5 To 42,5 DegreeC |
Pressure Dew Points | -40 DegreeC |
Average Compressed Air Consumption | 0% |
Product Code: R-DRY BVA series
R-DRY BVA series
R-DRY BVA 400-20000 adsorption dryers are designed for continuous separation of water vapour from compressed air thus lowering the dew point. R-Dry BVA dryers have two columns that operate alternately. Adsorption takes place under pressure in the first column while the second column regenerates (heated ambient air for desorption + ambient air in vacuum mode for cooling). BVA type of dryer is suitable for applications running at mild ambient conditions. Due to regeneration in vacuum mode BVA type of dryers don’t consume any compressed air for the operation. A dryer consists of two columns, filled with desiccant beads, a blower, heater, controller with an LCD display, valves, manometers, and a support construction. A proven and robust design enables efficient and reliable operation, fast installation and simple maintenance.
Product Details:
Usage/Application | Compressed Air Systems |
Flow Rate | 19 To 144 Nm3/h |
Operating Pressure | 16 (14) Bar |
Max. Ambient Temp. | 1,5 To 55 DegreeC |
Pressure Dew Points | 3 DegreeC |
Standard Colour | RAL 5012 |
Product Code: OSL series
OSL series
OSL dryer series utilises a natural evolution of the patented ALU-DRY heat exchanger which is already established and well known for its high efficiency. This new version is designed with easy to fit air connections which improves the internal flow pattern. Compact size, optimized layout and innovative solutions reduce manufacturing costs whilst maintaining the same levels of reliability, quality and attention to details. OSL dryer series is designed and manufactured with respect to the environment using R134a ozone friendly refrigerant and completely recyclable materials.
Product Details:
Air Compressor Model | BF HP series |
Operating Pressure | 25, 50 Bar |
Volume Flow Rate | 1680 To 31400 Nm3/h |
Connections | DN80 To DN300 |
Operating Temp. Range | 1,5 To 65 DegreeC |
Standard Colour | RAL 5012 |
BF HP filters are designed for protection of the downstream compressed air system and equipment against defects and other failures in high pressure applications. Due to their robust welded carbon steel construction, are used for installation in heavy industrial applications with high air flows.They ensure high efficient removal of solid particles, water, oil aerosols, hydrocarbons, odour and vapours from compressed air systems up to 25 or upo to 50 bar. Required compressed air quality according to standard ISO 8571-1 can be achieved with 6 different grades of filter elements (B, P, R, M, S and A). Optional external condensate drains should be used for efficient condensate draining from filter housing. Fluid group 1 on request.
Product Details:
Usage/Application | High Temperature Compressed Air Systems |
Automation Grade | Automatic |
Flow Rate | 45 To 256 Nm3/h |
Operating Pressure | Upto 14 (16) Bar |
Operating Temp. Range | Upto 90 DegreeC |
Pressure Dew Points | 7 DegreeC |
Standard Colour | RAL 5012 |
Product Code: OMH refrigeration air dryer
OMH refrigeration air dryers
OMH refrigeration air dryer is synonymous of quality/performance at high temperature. It incorporates a dryer and aftercooler in a single unit; its strong point is that it includes all the latest technologies in a compact design without sacrifing perfomance in extreme operating conditions. The OMH refrigeration air dryers was designed in the utmost respect for the environment thanks to the use of ecological refrigerant fluids and the choice of recyclable manufacturing materials. Compressed air treated with OMH dryer series guarantees high quality standards, conforming to ISO 8573.1, in fact they respect Class 6 for residual humidity and Class 3 for maximum concentration of solid contaminants.
Product Details:
Usage/Application | Compressed Air Systems |
Flow Rate | 19 To 13248 Nm3/h |
Operating Pressure | Upto 14 Bar |
Max. Ambient Temp. | 45 DegreeC |
Pressure Dew Points | 3 DegreeC |
Max. Inlet Air Temp | 55 DegreeC |
Standard Colour | RAL 5012 |
Product Code: OMD refrigerant air dryers
OMD refrigerant air dryers
OMD refrigerant air dryer has been designed to lower the dew point in compressed air system by cooling the inlet air. By this water vapour retention of air drops significantly. The excess water condenses and is drained out of the system. Refrigerant air dryers are dimensioned to correspond to compressors from 3 kw-120 kw with output flow of 19 Nm3/h – 13.248 Nm3/h. OMD refrigerant air dryers achieve excellent performance even in instances of high ambient and high inlet temperatures. The highly efficient and ultra compact heat exchanger is able to operate effectively in ambient temperatures up to 45°C and inlet temperatures of 55°C, ensuring a reduced compressed air pressure drop.
Product Details:
Usage/Application | Compressed Air Systems |
Flow Rate | 390 To 20.200 Nm3/h |
Operating Pressure | 4 To 11 Bar |
Inlet Air Temperature Range | 140 To 200 DegreeC |
Pressure Dew Points | -20 DegreeC |
Average Compressed Air Consumption | 0 % |
Product Code: RC-DRY series
RC-DRY series
RC-DRY adsorption dryers have been designed for continuous separation of water vapour from compressed air thus reducing dew point. Operation of dryer requires two columns operated alternately. Heat of compression dryers do not need any additional source of energy to regenerate the adsorbent as they fully or partially utilise the heat generated during compression of the air in the compressor. Adsorption as well as regeneration take place under pressure meaning no compressed air is wasted for depressurisation. A dryer consists of two columns, filled with desiccant beads, water cooled heat exchangers, controller with LCD display, valves, manometers, and support construction. Proven robust design enables efficient and reliable operation, fast installation and simple maintenance
Product Details:
Usage/Application | Compressed Air Systems |
Automation Grade | Automatic |
Flow Rate | 1200 To 6500 Nm3/h |
Operating Pressure | 4 To 16 Bar |
Operating Temp. Range | 1,5 To 60 DegreeC |
Pressure Dew Points | -40 DegreeC ( -25 DegreeC / -70 DegreeC) |
Standard Colour | RAL 5012 |
Average Compressed Air Consumption | 15-20% |
Product Code: F-DRY series
F-DRY series
F-DRY adsorption dryers are designed for continuous separation of water vapour from the compressed air thus reducing pressure dew point. F-DRY series dryer consists of two columns, filled with desiccant beds, controller with LCD display, valves, manometers, support construction and suitable filter housings with the required filter element. Adsorption takes place under pressure in the first column while the second column regenerates with a portion of already dried compressed air at ambient pressure. When the first column is saturated to a certain level column switch-over is carried out and the process of adsorption continues in the second column without any drop of pressure at the outlet of the dryer. Regeneration of saturated desiccant is possible because a small portion of already dry compressed air is decompressed and when expanded it becomes extremely dry.
Product Details:
Drying Capacity | 0-20 cfm |
Dryer Technology | Nitrogenium |
Minimum Output Dew Point | -70 C |
Maximum Pressure | 16 |
Warranty | 12 months |
Frequency | 50/60Hz |
Color | RAL 5012 |
Weight | 10.5 |
Air Inlet Temperature | 6 Nm3/h |
Flow Rate | 6 Nm3/h |
I Deal In | New Only |